Calibration Failed Initial Tension (Fault 1104)
Possible Cause Action Notes
1 Ribbon
Ö
Check that the ribbon path is
correct and the Controller is
configured
Ö
The ribbon may have broken or been incorrectly
fitted e.g. path wrong and/or supply / waste the
wrong way round
Outside wound ribbon can not be used
TTR Page
33
2 Cassette
Ö
Check the handing is correct
Check the Ribbon Control
Sensor Slide moves freely
Check the Ribbon Core is not
slipping.
Try a known working Cassette
Ö
Ribbon core slipping – check the spools do not
move within the ribbon core.
Re-handing the Cassette Page
235
Repl
acing the Ribbon Control Sensor Roller
Assembly Page
228
3
Ribbon Control
Sensor
Ö
Check the Ribbon Control
Sensor is working correctly.
Replace the Ribbon Control
Sensor.
Ö
Observe the output of the Ribbon Control Sensor
in the Engineering/Diagnostics/Internal Menu. Use
a finger to apply pressure to the sensor and
observe the reading change.
Replacing the Ribbon Control Sensor Page
226
4 Printer
Ö
Replace the Printer PCB or
replace the Printer
Ö
Replacing the Printer PCB Page 226
Repl
acing the Printer: Refer to User Manual