Troubleshooting Guide
SmartDate X40 BFSE Version 1.0 Feb 2011
189/286
Calibration Diameter Out Of Range (Fault 1106)
Possible Cause Action Notes
1 Ribbon
Ö
Check that the ribbon path is
correct and the Controller is
configured
Ö
Outside wound ribbons cannot be used. The ribbon
may have broken or been incorrectly fitted e.g. path
wrong and/or supply / waste the wrong way round
TTR Page
33
2 Cassette
Ö
Check the handing is correct.
The Ribbon Core is not slipping.
If it is replace the ribbon and/or
the spools.
Try a known working Cassette.
Ö
Ribbon Core slipping – check the spools do not
move within the Ribbon Core.
Re-handing the Cassette Page 235
3 Movement roller
Ö
Check the operation of the
Ribbon Movement Roller
Ö
Replacing the movement roller Page xx
4 Printer
Ö
Replace the Printer PCB or
replace the Printer
Ö
Replacing the Printer PCB Page
226
Repl
acing the Printer: Refer to User Manual