After Sales
SmartDate X40 BFSE Version 1.0 Feb 2011
200/286
■ Preventative Maintenance
Introduction
This section is designed to provide information about how to keep the SmartDate X40 in
good working order.
Topics covered in this section include:
• Regular Checks
• General cleaning and care
• Care of Printhead
Regular Checks
To maintain consistent high quality performance from the SmartDate X40, these checks
should be performed at least once per week.
• Check the ribbon is tracking through the Cassette correctly
• Pull the ribbon through by hand and check there is no ribbon creasing across its
width
• Check the Peel Roller for build up of ink. Remove using Isopropanol wipes
•
Check the air supply is at the correct pressure and is dry and uncontaminated
• Check the condition of the bracket Print Roller or Platen. To maintain print quality,
the Print Roller or Platen should be smooth and free from debris. Replace if
necessary
• Check the condition of the mains cable, replace if damaged
• Check the condition of the interconnecting and other cables, replace if damaged.
Make sure the cable retaining screws are tightened