Julian
Anaesthetic Workstation
Instructions for Use
Software 2.n
1-36-96
"Only for internal use by Draeger. Not applicable as Instructions for Use!"

Table of Contents

Other manuals for Dräger Julian

Question and Answer IconNeed help?

Do you have a question about the Dräger Julian and is the answer not in the manual?

Dräger Julian Specifications

General IconGeneral
CategoryAnesthesia Workstation
Gas SupplyO2, N2O, Air
PEEP0 to 20 cmH2O
TypeAnesthesia Machine
Ventilation ModesSIMV
Tidal Volume Range20 to 1400 mL
VaporizersSevoflurane, Isoflurane
MonitoringO2, CO2, N2O, anesthetic agent, pressure, volume, flow
Tidal Volume20 to 1400 mL
Respiratory Rate4 to 60 breaths per minute
FiO2 Range21-100%
WeightApproximately 120 kg

Summary

For Your Safety and that of Your Patients

Intended Use

Operating Concept

Selecting / setting ventilation parameters

Guides on how to adjust ventilation settings like PEEP using the system controls.

Before Using for the First Time

Charging the battery for emergency operation

Instructions for charging the internal UPS battery before initial use of the workstation.

Preparation

Connecting the gas supply

Steps for connecting central gas supply hoses to the workstation's gas block.

Connecting the backup gas cylinders for O2 and N2O

Procedure for installing and connecting O2 and N2O cylinders as a backup supply.

Connecting the power supply

Steps for connecting the workstation to the mains power socket and equipotential bonding.

Starting Up

Checking the workstation against the checklist

Guided procedure to verify all components are correctly connected and functional before operation.

Self-test Procedures

Outlines the automatic system self-test process and its components.

Operation

Setting the fresh gas concentrations

How to adjust carrier gas, O2 concentration, and fresh gas flow settings via the interface.

Selecting the ventilation mode

Guide to choosing and configuring ventilation modes like MAN/SPONT, IPPV, and PCV.

Monitoring

Alarm Management

Guidance on setting, displaying, and managing alarms, including AutoSet and CO2 alarms.

Configuration and Calibration

Steps for configuring operational settings, monitoring parameters, and performing system calibrations.

Maintenance Intervals

Fault – Cause – Remedy

Related product manuals