EasyManua.ls Logo

DURKOPP ADLER 650-10 - Page 153

DURKOPP ADLER 650-10
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions 650-10 - 03.0 - 08/2016 151
2462 Error U-axis stepper motor
disturbance (IDMA auto
increment)
Switch the machine off and
on again
2471 Error Watchdog Switch the machine off and
on again
Perform a software update
Contact customer service
2472 Error Stepper motor overvoltage:
Stepper motor card
def
ective
Replace the control
2473 Error U-axis stepper motor over
cu
rrent error
Check the connection
Test stepper motor phases
(R = 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2474 Error Software error Perform reset
Perform a software update
Contact customer service
2475 Error Magnet wheel search Check the connection
Test stepper motor phases
(R = 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2477 Error Stepper motor overload (I²T) Remove the cause of the
stif
f movement or blockage
Replace the stepper motor
Replace the control
2478 Error Encoder error Check the connection of
the encoder cable and
replace
, if necessary
Replace the control
2479 Error Current sensor:
Stepper motor card
def
ective
Controller defective
Replace the control
Code Type Possible causes Remedial action