Troubleshooting
Operating Instructions 650-10 - 03.0 - 08/2016 153
2901 Error Referencing timeout Switch the machine off and
on again
Check the clamping of the
stepp
er motor
3010 Error Controller: 100 V voltage
err
or
Check the connections
Replace the control
3011 Error Controller: 100 V voltage
err
or
Check the connections
Replace the control
3012 Error Controller: 100 V voltage
e
rror (I²T)
Switch the machine off and
on again
Check the connections
Replace the control
3020 Error Short circuit in 24 V input or
output
Check the connections
Replace the control
3021 Error Short circuit in 24 V input or
output
Check the connections
Replace the control
3022 Error Short circuit in 24 V input or
output (
I²T)
Switch the machine off and
on again
Check the connections
Replace the control
3030 Error Sewing motor phase error Test sewing motor phases
(R = 2.8, high impedance
to PE)
Replace the encoder
Replace the sewing motor
Replace the control
3104 Warning Pedal not in rest position
Setpoint device defective
Do not step on the Pedal
when st
arting up
the machine
Replace the setpoint device
4440
4459
Error OP3000 control panel:
Internal error
Switch the machine off and
on again
Perform a software update
Replace the control panel