Programming
Service Instructions 869-M PREMIUM - 00.0 - 07/2018 105
19.6.10 Setting the Motor holding force (Holding Force) parameter
Various settings can be made for the holding force of the motor.
The possibilities are explained in more detail in the table.
BRM Bobbin rotation monitor
(Value range: On/Off)
Stitches
Delayed stitches before the bobbin rotation monitor starts. The machine
calculates the number of stitches automatically depending on the value
entered.
(Value range 000 – 255)
MsgAfterTrim If detecting an error during the enlacement check or while monitoring
the bobbin rotation, the machine will indicate an error message during
the seam, which must be confirmed with OK. The error disappears.
If the parameter MsgAfterTrim is active, the error will be displayed
again after the seam has been completed.
(Value range: On/Off)
StopConfirm If detecting an error during the enlacement check or while monitoring
the bobbin rotation, the machine will indicate an error message and
stop. You must confirm this error before you can resume sewing.
(Value range: On/Off)
Menu item Setting options
Menu item Setting options
Mode Off
Holding force inactive
On
Holding force active
Hold Pos.
Position control; position is checked and resets itself
Max.Current Holding current of the motor
(Value range 00 – 50)
Response Response time for the continuous current