Programming
Service Instructions 869-M PREMIUM - 00.0 - 07/2018 121
19.7.11 Setting the Access rights (Lock) parameter
The access to certain functions and areas can be restricted for the user.
If an access lock is set, it is shown in both the Manual and Automatic
modes. A key symbol appears on the display, on the right next to the
program number.
Various settings can be made for the access rights. The possibilities are
explained in more detail in the table.
Menu item Setting option
Password Set your own access password for the Technician level. 00000 corre-
sponds to the password preset by Dürkopp Adler. Do not lose the new
password!
(Value range 00000 – 99999)
Key Mode for accessing the Technician level
Code Access via defined password only
USB Access via USB key with access file only
USB + Code Access via defined password or USB key with
access file.
Security Key The defined password is saved as a file to a USB key. The USB key
provides access with this password on all machines. The file stored
on the USB key cannot be copied.
Prog.Switch The last active program is fixed on the Operator level. It is not possi-
ble to change to a different program.
(Value range: On/Off)
Manual Selective restriction of areas in Manual mode
R/W – Read/Write
Off – Area is hidden
R/O – Read Only
Parameter Restriction of access to the parameters
(Value range R/W, Off)
Stitch length Restriction of access to the stitch length
(Value range R/W, OFF, R/O)
Thr.Tens. Restriction of access to the needle thread tension
(Value range R/W, OFF, R/O)
Foot Press. Restriction of access to the foot pressure
(Value range R/W, OFF, R/O)
Foot Stroke Restriction of access to the sewing foot stroke
(Value range R/W, OFF, R/O)