SV-EMS-220 Installation and Configuration
SkyView System Installation Guide - Revision K 7-51
Preset Fuel Capacitythis can be used to quickly recall a second, non-full starting fuel
state. For example, if your tanks have tabs so that you can easily fill to ¾ of your normal
full fuel load, you would enter this number here so that you can quickly set your fuel
computer to this second preset when you fill to the tabs.
Fuel Added DetectWhen set to yes, SkyView will check for discrepancies between the
physical fuel quantity senders and the fuel computer’s calculated fuel load on boot-up.
If one is found, SkyView will prompt the user to adjust the fuel computer’s fuel state.
This option should only be set to YES on one display if you have more than one in the
system.
Manual EMS Sensor Settings Configuration
Go to the Sensor Setup Menu (SETUP MENU > EMS SETUP > SENSOR SETUP) to manually
configure the settings of an EMS sensor. Once there, a list of every mapped sensor is displayed.
Follow this basic procedure to configure sensor settings:
1. Choose a sensor. Scroll through the menu to a sensor and move the joystick right to
enter to the sensor configuration menu.
2. Set the alarm. Scroll to the ALARM configuration line, move the joystick right to enter
the Alarm Adjust Menu, choose the appropriate alarm for the sensor, and then press
ACCEPT. Press BACK to return to the sensor configuration menu.
3. Set the graphical display limits. Scroll to the MAXIMUM and MINIMUM GRAPHICAL
DISPLAY lines, move the joystick right to enter the respective menus, adjust the values
appropriately - and then press ACCEPT. Press BACK to return to the sensor configuration
menu.
4. Set the ranges. Scroll the menu and configure enable, color, and top and bottom.
5. Save the settings. Press BACK to return to the Sensor Setup Menu. Press EXIT to return
to the Main Menu.
The examples on the following pages show four configured sensors: a voltmeter, a contact,
RPM, and an oil temperature sensor.