SkyView System Installation Guide - Revision K 7-1
7. SV-EMS-220 Installation and Configuration
This chapter contains information and diagrams that specifically apply to the installation of the
SV-EMS-220 Engine Monitoring module and compatible transducers and sensors. After reading
this chapter, you should be able to determine how to prepare an installation location, how to
mount the module and its transducers and sensors, how to make all necessary electrical and
transducer and sensor connections, and also how to configure the SkyView system for the
installations engine parameter sensing.
Note that Dynon provides preconfigured sensor mapping and settings files as well as premade
engine sensor connection wire harnesses. These resources support many popular four and six-
cylinder engine installations. Reference the Example Engine Sensor and Transducer Installations
Section for examples.
Figure 23 is a high-level overview of a suggested installation, configuration, and calibration
procedure for the SV-EMS-220 and its associated wiring, sensors, and transducers.
Choose a
location based on
Location
Requirements
Section
Install SkyView
network cabling
Prepare the
location
Install engine
sensors and
transducers
Install EMS
module with
electrical
connections
Configure
EMS-related
settings on
SkyView display
Perform
EMS-related
calibrations
*Assumes SV-D700 or SV-D1000 is properly installed and working.
Plan sensor and
transducer
installation
Obtain wire
harnesses,
sensors,
transducers, etc.
Research Dynon
presupported
engine
installations
Understand
presupported
engine
installation
Install
EMS-specific wire
harnesses
Configure
SkyView Network*
Engine
presupported?
Yes
No
Check for and install
EMS sensor definition
and configuration file
updates
Figure 23Suggested SV-EMS-220 Installation and Configuration Procedure