Basic SkyView Display Operation
3-14 SkyView System Installation Guide - Revision K
How to Export System Settings
This operation creates a set of files on the USB flash drive that contain display
settings, equipment settings, and important calibration information. All of the
filenames contain the tail number and the firmware version.
1. Insert the USB flash drive into one of the display’s USB sockets.
2. Go to the Export Settings Wizard (SETUP MENU > SYSTEM SOFTWARE > EXPORT
SETTINGS…).
3. Create a file name for the settings file.
4. Save the settings file onto the flash drive by pressing EXPORT or press CANCEL to return
to the System Software Menu.
How to Load and Delete Files
5. Download file from downloads.dynonavionics.com such as terrain or EMS files or use
another source for the SkyView file.
6. Copy the file onto your USB flash drive. The file must be in the root directory of the drive
in order to be recognizable by the display.
7. Insert the USB flash drive into one of the display’s USB sockets.
8. Go to the Load Files Wizard (SETUP MENU > SYSTEM SOFTWARE > LOAD FILES…).
9. Select a file and press:
a. LOAD to load the file onto the system.
b. CANCEL to return to the System Software Menu.
c. REMOVE to delete the file from the USB flash drive.