116
9. Monitoring Station
9.1 Basic Overview
The data transmission from ESIM264 alarm system to monitoring station can be carried out by one of the following communication
methods at a time:
GPRS Network;
Voice Calls (GSM Audio);
RS485 Interface;
CSD (Circuit Switched Data).
The system supports 1 primary communication and up to 3 backup communications. All of the aforementioned communication
methods can be set up as primary or backup in any sequence order by EKB2 keyboard, EKB3 keyboard and ELDES Conguration Tool
software. For more details, please, refer to softwares HELP section and chapter 9.3 Monitoring Station Parameter Conguration
(SMS, EKB2, EKB3).
ATTENTION: ESIM264 system is fully compatible with Kronos NET/Kronos LT monitoring station software for communication via
GPRS network. When using dierent monitoring station software, EGR100 GPRS software is necessary. EGR100 is freeware and can
be downloaded at www.eldes.lt
9.2 Event Messages
The event messages can either be transmitted to monitoring station alone or to monitoring station with duplication by SMS (user
messages) to User1 phone number.
The following table provides the CID codes of events supported by ESIM264 alarm system:
Seq. No. Contact ID® Code Event Description Duplication by SMS
1 1110 Fire Zone Alarm
*
2 3111 Fire Zone Restore
3 1121 Armed by User (Duress Password)
**
4 3121 Disarmed by User (Duress Password)
**
5 1130 Burglary Alarm
*
6 3130 Burglary Restore
7 1133 24H Zone Alarm
*
8 3133 24H Zone Restore
9 1144 Tamper Alarm
10 3144 Tamper Restore
11 1146 Silent Zone Alarm
*
12 3146 Silent Zone Restore
13 1158 Temperature Exceeded
14 1159 Temperature Fallen
15 1301 Main Power Loss
16 3301 Main Power Restore
17 1302 Wireless Sensor Low Battery
18 1308 Device Shut Down
19 1311 ESIM264 Backup Battery Fail
20 1381 Wireless Signal Loss
***
21 3381 Wireless Signal Restore
22 1401 Armed by User
23 3401 Disarmed by User
24 1456 Armed by User (Stay Mode)
**
25 3456 Disarmed by User (Stay Mode)
**
26 1463 Armed by User (SGS Password)
**
27 3463 Disarmed by User (SGS Password)
**
28 1602 Periodical Test
29 1900 Device Started

Table of Contents