EasyManua.ls Logo

Eldes ESIM264 - Voice Calls Settings

Default Icon
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MANUAL ELDES ESIM264 V2.0 127
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION DEVICE ID [XXXX]
Value: [XXXX] – 4 digit device ID code, range – [0000... 9999]
EKB3
Enter parameter 47 & Device ID code:
[47xxxx#]
Value: xxxx – 4 digit device ID code, range – [0000... 9999]
The 4-digit ID code of the alarm system intended for system identication by EGR100 softwa-
re. This ID code is indicated as Unit ID in EGR100 software.
This parameter can be set and edited using ELDES Conguration Tool and SMS only.
Device ID (GPRS)
9.3.3 Voice Calls Settings
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET
ARC STATION NUM TEL. NUMBER [1... 3] [XXXXXXXXXXXXXXX]
Value: [XXXXXXXXXXXXXXX] – up to 15 digits phone number
EKB3
Enter parameter 26, number of phone number entry & phone number
[26xxyyyyyyyyyyyyyyy#]
Value: xx – number of monitoring station phone number entry, range – [01...
03]; yyyyyyyyyyyyyyy – up to 15 digits phone number
The system supports up to 3 monitoring station phone numbers for communication with the
alarm system via voice calls (GSM audio channel). Tel. Number 1 is mandatory, the other two
are not necessary. All numbers must be entered starting with international country code e.g.
44[area code][local number]. The plus character is not necessary.
Set Monitoring
Station Phone
Number (Voice Calls)

Table of Contents

Other manuals for Eldes ESIM264

Related product manuals