MANUAL ELDES ESIM264 V2.0 73
SMS
SMS text:
XXXX_fota:ftp-server-IP,port,rmware-le-name.bin,user-name,password
Value: ftp-server-IP - IP address of FTP server where ESIM264 rmware le is
stored; port - port number of FTP server (usually - 21); rmware-le-name.bin -
name of the rmware le; user-name - user name of FTP server login; password
- password of FTP server login.
Example: 1111_fota:84.15.143.111,21,esim264fw.bin,eldesuser,eldespassword
ESIM264 alarm system supports FOTA (rmware-on-the-air) feature. This allows to upgrade
the rmware remotely via GPRS connection. Once the upgrade process is initiated, the system
connects to the specied FTP server address where the rmware le is hosted and begins
downloading and re-ashing the rmware. In order to initiate the upgrade process, please,
send the following SMS message.
FOTA
6.6 Upgrading the Firmware via GPRS Connection (FOTA)
ATTENTION: “ELDES UAB” does not run a FTP server and does not host the rmware les online. Please, contact ELDES technical
support to request the latest rmware le: support@eldes.lt
NOTE: It is strongly recommended to restore default parameters after the rmware upgrade.