MANUAL ELDES ESIM264 V2.0 35
XXXX_INOUT:YY:ZZ
Value: YY - Entry Delay duration in seconds, range - [0... 65535]; ZZ - Exit Delay du-
ration in seconds, range - [0... 600]
Example: 1111_INOUT:25:14
Menu path:
OK CONFIGURATION PRIMARY SETTINGS EXIT DELAY [XXX]
Value: [XXX]– Exit Delay duration in seconds, range – [0... 600]
Enter parameter 72 & exit delay duration:
[72xxz#]
Value: xxx – Exit Delay duration in seconds, range – [0... 600]
EKB2
EKB3
Exit Delay is a period of time intended for user to leave the secured area. The system begins the
countdown after the arming process initiation. The default Exit Delay du ration is 15 seconds.
Set Exit Delay
SMS
N/A
Menu path:
OK CONFIGURATION ZONES ATZ MODE ENABLE
Enter parameter 28 & parameter status value:
[281#]
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ZONES ATZ MODE DISABLE
EKB3
Enter parameter 28 & parameter status value:
[280#]
EKB2
EKB3
ATZ mode activates zone duplication increasing number of on-board zones from 6 to 12. By
default ATZ mode is disabled.
This command disables ATZ mode.
Enable ATZ Mode
Disable ATZ Mode