Troubleshooting Promag 53 PROFIBUS DP/PA
140 Endress+Hauser
691 S: SIM. FAILSAFE
!: # 691
0x48
0x49
0x4A
UNCERTAIN Substitute
set
(Substitute
set of failsafe
status)
O.K.
Low
High
Simulation
failsafe active
Cause:
Simulation of failsafe mode (outputs) is active.
Remedy:
Switch off simulation.
Access:
SUPERVISION SYSTEM OPERATION
SIM. FAILSAFE MODE ( OFF)
692 S: SIM. MEASURAND
!: # 692
0x60
0x61
0x62
UNCERTAIN Simulated
Value
(manually
specified
value)
O.K.
Low
High
Simulation
measured value
active
Cause:
Simulation of the measured value is active.
Remedy:
Switch off simulation.
Access:
SUPERVISION SYSTEM OPERATION
SIM. MEASURAND ( OFF)
698 S: DEV. TEST ACT.
!: # 698
0x60
0x61
0x62
UNCERTAIN Simulated
Value
(manually
specified
value)
O.K.
Low
High
Device test via
Fieldcheck active
Cause:
The measuring device is being checked on site
via the test and simulation device.
No. Device status message
(local display)
PROFIBUS measured value status
Extended
diagnostic
message in the
PROFIBUS
master
Cause/remedy
(Spare parts 146)
Quality code (HEX)
Measured value status
Quality status
Quality substatus
Limits