3 Block MEASURED VARIABLES Device Functions Proline Promass 83 FOUNDATION Fieldbus
12 Endress+Hauser
CORRECTED
TARGET VOLUME FLOW
(0024)
! Note!
This function is not available unless % MASS / % VOLUME was selected in the
DENSITY FUNCTION function (7000).
Use this function to display the currently measured corrected volume flow of the target
fluid. Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
CARRIER
MASS FLOW
(0025)
! Note!
This function is not available unless one of the following was selected:
• In the DENSITY FUNCTION function (7000):
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % MASS 2D or % MASS 3D.
Use this function to display the currently measured mass flow of the carrier fluid.
Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
% CARRIER
MASS FLOW
(0026)
! Note!
This function is not available unless one of the following was selected:
• In the DENSITY FUNCTION function (7000):
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % MASS 2D or % MASS 3D.
Use this function to display the currently measured mass flow of the carrier fluid as a %
(of the overall mass flow). Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
CARRIER
VOLUME FLOW
(0027)
! Note!
This function is not available unless one of the following was selected:
• In the DENSITY FUNCTION function (7000):
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % VOLUME 2D or
% VOLUME 3D.
Use this function to display the currently measured volume flow of the carrier fluid.
Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
% CARRIER
VOLUME FLOW
(0028)
! Note!
This function is not available unless one of the following was selected:
• In the DENSITY FUNCTION function (7000):
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % VOLUME 2D or
% VOLUME 3D.
Use this function to display the currently measured volume flow of the carrier fluid as a %
(of the overall mass flow). Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
Function description
MEASURED VARIABLES → MEASURING VALUES → ADDITIONAL VALUES