Device Functions Proline Promass 83 FOUNDATION Fieldbus 6 Block TOTALIZER
Endress+Hauser 47
6.2 Group HANDLING TOTALIZER
TOTALIZER D
⇒
TOTALIZER 1 DAA
⇓
TOTALIZER 2 DAB
⇓
TOTALIZER 3 DAC
⇓
INVENTORY DGA
⇓
HANDLING TOTALIZER DJA
⇒
Handling totalizer functions
Function description
TOTALIZER → HANDLING TOTALIZER → Handling totalizer functions
RESET ALL
TOTALIZERS
(3800)
Use this function to reset the totals (including all overflows) of the totalizers (1 to 3) to
zero (= RESET).
Options:
NO
YES
Factory setting:
NO
FAILSAFE MODE
(3801)
Use this function to define the common response of all totalizers (1 to 3) in case of
error.
Options:
STOP
The totalizers are paused until the fault is rectified.
ACTUAL VALUE
The totalizers continue to count based on the current flow measured value. The fault is
ignored.
HOLD VALUE
The totalizers continue to count the flow based on the last valid flow value (before the
fault occurred).
Factory setting:
STOP