Device Functions Proline Promass 83 FOUNDATION Fieldbus Table of contents for FOUNDATION Fieldbus
Endress+Hauser 103
Table of contents for FOUNDATION Fieldbus
1 Operation via
FOUNDATION Fieldbus. . . . . . . . . . 104
1.1 Block model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
2 Resource Block. . . . . . . . . . . . . . . . . 106
2.1 Selecting the operating mode . . . . . . . . . . . . . . . . 106
2.2 Block status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
2.3 Write protection and simulation . . . . . . . . . . . . . . 106
2.4 Alarm detection and processing . . . . . . . . . . . . . . 107
2.5 Resource Block parameters . . . . . . . . . . . . . . . . . . 108
3 Transducer Block . . . . . . . . . . . . . . 109
3.1 Signal processing . . . . . . . . . . . . . . . . . . . . . . . . . 110
3.2 Important functions and parameters
of the Transducer Blocks . . . . . . . . . . . . . . . . . . . 111
3.2.1 Block output values . . . . . . . . . . . . . . . . . 111
3.2.2 Selecting the operating mode . . . . . . . . . . 112
3.2.3 Alarm detection and processing . . . . . . . . 112
3.2.4 Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . 113
3.2.5 Accessing the device-specific parameters. . 113
3.3 "Flow" Transducer Block parameters. . . . . . . . . . . 113
3.4 "Diagnosis" Transducer Block parameters . . . . . . . 131
3.5 "Display" Transducer Block parameters . . . . . . . . . 134
3.6 "Totalizer" Transducer Block parameters . . . . . . . . 151
3.7 "Calculated Density" Transducer Block parameters 155
3.8 "Viscosity" Transducer Block parameters . . . . . . . . 166
3.9 "Advanced Diagnostics"
Transducer Block parameters . . . . . . . . . . . . . . . . 169
4 Function blocks . . . . . . . . . . . . . . . . 180
5 Analog Input function block . . . . . . . 181
5.1 Signal processing . . . . . . . . . . . . . . . . . . . . . . . . . 181
5.2 Important functions and parameters of the
Analog Input function blocks . . . . . . . . . . . . . . . . 183
5.2.1 Selecting the operating mode . . . . . . . . . . 183
5.2.2 Assignment of the process variable . . . . . . 183
5.2.3 Linearization types . . . . . . . . . . . . . . . . . . 183
5.2.4 Selection of units . . . . . . . . . . . . . . . . . . . 184
5.2.5 Status of the output value OUT. . . . . . . . . 184
5.2.6 Simulation of input/output. . . . . . . . . . . . 185
5.2.7 Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . 185
5.2.8 Rescaling the input value . . . . . . . . . . . . . 185
5.2.9 Limit values . . . . . . . . . . . . . . . . . . . . . . . 186
5.2.10 Alarm detection and processing . . . . . . . . 186
6 Discrete Output function block . . . . . 188
6.1 Signal processing. . . . . . . . . . . . . . . . . . . . . . . . . . 188
6.2 Important functions and parameters of
the Discrete Output function block . . . . . . . . . . . . 189
6.2.1 Selecting the operating mode . . . . . . . . . . 189
6.2.2 Safety behavior . . . . . . . . . . . . . . . . . . . . . 189
6.2.3 Assignment between the Discrete Output
function block and the Transducer Block. . 189
6.2.4 Values for the parameters CAS_IN_D,
RCAS_IN_D, OUT_D, and SP_D . . . . . . . 190
7 Additional function blocks. . . . . . . . . 192
8 Factory settings . . . . . . . . . . . . . . . . . 193
8.1 SI units (not for USA and Canada). . . . . . . . . . . . . 193
8.1.1 Low flow cut off, full scale value,
pulse value . . . . . . . . . . . . . . . . . . . . . . . . 193
8.1.2 Language . . . . . . . . . . . . . . . . . . . . . . . . 193
8.1.3 Density, length, temperature. . . . . . . . . . . 194
8.2 US units (only for USA and Canada) . . . . . . . . . . . 194
8.2.1 Low flow cut off, full scale value,
pulse value . . . . . . . . . . . . . . . . . . . . . . . . 194
8.2.2 Language, density, length, temperature . . . 194
9 Index FOUNDATION Fieldbus . . . . . 195