Device Functions Proline Promass 83 FOUNDATION Fieldbus 4 Block QUICK SETUP
Endress+Hauser 21
4.2 Quick Setup "Gas Measurement"
!
Note!
The procedure is described in detail in the Operating Instructions for
Proline Promass 83 FOUNDATION Fieldbus, BA065D/06/en.
A0002618-en
Settings for the Gas Measurement Setup menu:
Fct. code Function name Suggested settings Description
Call up through the function matrix:
B QUICK SETUP QS-GAS MEASURE Page 19
1004 QS-GAS MEASURE YES Page 19
Basic configuration:
6420 EMPTY PIPE DETECTION No entry possible, the selection changes
automatically to OFF.
Page 54
6400 ASSIGN LOW FLOW CUT OFF For gas measurement we recommend
to switch off the low flow cut off.
OFF
Page 52
6402 ON-VALUE LOW FLOW CUT
OFF
If you do not switch off the low flow cut off:
0.0000
Page 52
6403 OFF-VALUE LOW FLOW CUT
OFF
If you do not switch off the low flow cut off:
50%
Page 52
+
+
E