Device Functions Proline Promass 83 FOUNDATION Fieldbus 6 Block TOTALIZER
Endress+Hauser 45
UNIT TOTALIZER
(3001)
Use this function to define the unit for the totalizer's measured variable, as selected
beforehand.
Options (for the MASS FLOW assignment):
Metric → g; kg; t
US → oz; lb; ton
Factory setting:
kg
Options (for the VOLUME FLOW assignment):
Metric → cm
3
; dm
3
; m
3
; ml; l; hl; Ml Mega
US → cc; af; ft
3
; oz f; gal; Kgal; Mgal; bbl (normal fluids); bbl (beer);
bbl (petrochemicals); bbl (filling tanks)
Imperial → gal; Mgal; bbl (beer); bbl (petrochemicals)
Factory setting:
m
3
Options (for the CORRECTED VOLUME FLOW assignment):
Metric → Nl; Nm
3
US → Sm
3
; Scf
Factory setting:
Nm
3
! Note!
The unit selected here has no effect on the fieldbus. It is only used for the local display
and for assigned instrument functions.
TOTALIZER MODE
(3002)
Use this function to define how the flow components are to be totaled by the totalizer.
Options:
BALANCE
Positive and negative flow components. The positive and negative flow components are
balanced. In other words, net flow in the flow direction is registered.
FORWARD
Only positive flow components
REVERSE
Negative flow components only
Factory setting:
Totalizer 1 = BALANCE
Totalizer 2 = FORWARD
Totalizer 3 = REVERSE
RESET
TOTALIZERS
(3003)
Use this function to reset the sum and the overflow of the totalizer to zero.
Options:
NO
YES
Factory setting:
NO
Function description
TOTALIZER → TOTALIZERS (1 to 3) → CONFIGURATION