9 Block SUPERVISION Device Functions Proline Promass 83 FOUNDATION Fieldbus
84 Endress+Hauser
9.1 Group SYSTEM
9.1.1 Function group CONFIGURATION
SUPERVISION J
SYSTEM JAA
CONFIGURATION 800
Function description
SUPERVISION SYSTEM CONFIGURATION
ALARM DELAY
(8005)
Use this function to define a time span for which the criteria for an error have to be
satisfied without interruption before a fault or notice message is generated.
Depending on the setting and the type of error, this suppression acts on:
•Display
FOUNDATION Fieldbus
User input:
0 to 100 s (in steps of one second)
Factory setting:
0 s
" Caution!
If this function is activated, fault and notice messages are delayed by the time
corresponding to the setting before being transmitted to the higher-order controller
(process controller, etc.). It is therefore imperative to check in advance in order to make
sure whether a delay of this nature could affect the safety requirements of the process. If
fault and notice messages may not be suppressed, a value of 0 seconds must be entered
here.
REMOVE
SW-OPTION
(8006)
! Note!
This function is only available if:
The F-CHIP software options were saved beforehand
•The F-CHIP is not located on the I/O board of the measuring device
Deletes all F-CHIP software options, such as batching, density functions, etc.
Options:
NO
YES
Factory setting:
NO
" Caution!
If process variables which are only available via the F-CHIP software options are assigned
to the local display or the outputs, these have to be reconfigured. If reconfiguration does
not take place, the local display and the totalizer are set to the factory setting and the
outputs are set to OFF.
PERMANENT STORAGE
(8007)
This function indicates whether automatic, permanent storage of parameter changes in
the EEPROM is switched on or off.
Display:
OFF
ON
Factory setting:
ON
" Caution!
The selection for this function can only be changed by the Endress+Hauser service
organization.
If OFF is selected, all parameter changes are not permanently stored in the EEPROM.
This means that these parameter changes are no longer available after a power failure.
In these instances, the device starts with the parameter configurations last stored in
the EEPROM.