3 Block MEASURED VARIABLES Device Functions Proline Promass 83 FOUNDATION Fieldbus
14 Endress+Hauser
3.2 Group SYSTEM UNITS
3.2.1 Function group CONFIGURATION
MEASURED
VARIABLES
A
⇒
MEASURING VALUES AAA
⇓
SYSTEM UNITS ACA
⇒
CONFIGURATION 040
Function description
MEASURED VARIABLES → SYSTEM UNITS → CONFIGURATION
You can select the units for measured variables in this function group.
! Note!
The units selected here have no effect on the fieldbus. They are only used for the local display and for assigned
instrument functions.
UNIT MASS FLOW
(0400)
Use this function to select the unit for displaying the mass flow (mass/time).
The unit you select here is also valid for:
• Switching points (limit value for mass flow, flow direction)
• Low flow cut off
Options:
Metric:
Gram → g/s; g/min; g/h; g/day
Kilogram → kg/s; kg/min; kg/h; kg/day
Ton → t/s; t/min; t/h; t/day
US:
Ounce → oz/s; oz/min; oz/h; oz/day
Pound → lb/s; lb/min; lb/h; lb/day
Ton → ton/s; ton/min; ton/h; ton/day
Factory setting:
Depends on country (kg/h or US-lb/min)
UNIT MASS
(0401)
Use this function to select the unit for displaying the mass.
The unit you select here is also valid for:
• Pulse weighting (e.g. kg/p)
Options:
Metric → g; kg; t
US → oz; lb; ton
Factory setting:
Depends on country (kg or US-lb)
! Note!
The unit of the totalizers is independent of your choice here. The unit for each totalizer
is selected separately for the totalizer in question.