Proline Prosonic Flow P 500 HART Commissioning
Endress+Hauser 139
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Assign simulation process variable Select a process variable for
the simulation process that is
activated.
Off
Volume flow
Mass flow
Flow velocity
Sound velocity
Temperature
*
Pressure
*
Density
*
Reference density
*
S&W volume flow
*
GSV flow
*
NSV flow
*
API gravity
*
API slope
*
Off
Process variable value A process variable is selected
in the Assign simulation
process variable parameter
(→  139).
Enter the simulation value for
the selected process variable.
Depends on the
process variable
selected
0
Current output 1 to n simulation Switch the simulation of the
current output on and off.
Off
On
Off
Current output value In the Current output 1 to n
simulation parameter, the On
option is selected.
Enter the current value for
simulation.
3.59 to 22.5 mA 3.59 mA
Frequency output 1 to n simulation In the Operating mode
parameter, the Frequency
option is selected.
Switch the simulation of the
frequency output on and off.
Off
On
Off
Frequency output 1 to n value In the Frequency simulation
1 to n parameter, the On
option is selected.
Enter the frequency value for
the simulation.
0.0 to 12 500.0 Hz 0.0 Hz
Pulse output simulation 1 to n In the Operating mode
parameter, the Pulse option is
selected.
Set and switch off the pulse
output simulation.
For Fixed value option:
Pulse width parameter
(→  111) defines the
pulse width of the pulses
output.
Off
Fixed value
Down-counting
value
Off
Pulse value 1 to n In the Pulse output
simulation 1 to n parameter,
the Down-counting value
option is selected.
Enter the number of pulses for
simulation.
0 to 65 535 0
Switch output simulation 1 to n In the Operating mode
parameter, the Switch option
is selected.
Switch the simulation of the
switch output on and off.
Off
On
Off
Switch state 1 to n Select the status of the status
output for the simulation.
Open
Closed
Open
Relay output 1 to n simulation Switch simulation of the relay
output on and off.
Off
On
Off
Switch state 1 to n The On option is selected in
the Switch output simulation
1 to n parameter parameter.
Select status of the relay
output for the simulation.
Open
Closed
Open
Pulse output simulation Set and switch off the pulse
output simulation.
For Fixed value option:
Pulse width parameter
defines the pulse width
of the pulses output.
Off
Fixed value
Down-counting
value
Off

Table of Contents