Technical data Proline Prosonic Flow P 500 HART
210 Endress+Hauser
Operating elements
External operation via touch control (3 optical keys) without opening the housing: ,
, 
Operating elements also accessible in the various zones of the hazardous area
Remote operation →  82
Service interface →  83
Supported operating tools Different operating tools can be used for local or remote access to the measuring device.
Depending on the operating tool used, access is possible with different operating units and
via a variety of interfaces.
Supported operating
tools
Operating unit Interface Additional information
Web browser Notebook, PC or tablet
with web browser
CDI-RJ45 service
interface
WLAN interface
Special Documentation for
device
DeviceCare SFE100 Notebook, PC or tablet
with Microsoft Windows
system
CDI-RJ45 service
interface
WLAN interface
Fieldbus protocol
→  192
FieldCare SFE500 Notebook, PC or tablet
with Microsoft Windows
system
CDI-RJ45 service
interface
WLAN interface
Fieldbus protocol
→  192
Field Xpert SMT70/77/50 All Fieldbus protocols
WLAN interface
Bluetooth
CDI-RJ45 service
interface
Operating Instructions
BA01202S
Device description files:
Use update function of
handheld terminal
SmartBlue App Smart phone or tablet
with iOs or Android
WLAN →  192
Other operating tools based on FDT technology with a device driver such as DTM/
iDTM or DD/EDD can be used for device operation. These operating tools are available
from the individual manufacturers. Integration into the following operating tools,
among others, is supported:
FactoryTalk AssetCentre (FTAC) from Rockwell Automation →
www.rockwellautomation.com
Process Device Manager (PDM) from Siemens → www.siemens.com
Asset Management Solutions (AMS) from Emerson → www.emersonprocess.com
FieldCommunicator 375/475 from Emerson → www.emersonprocess.com
Field Device Manager (FDM) from Honeywell → www.process.honeywell.com
FieldMate from Yokogawa → www.yokogawa.com
PACTWare → www.pactware.com
The related device description files are available: www.endress.com → Download Area
Web server
With the integrated web server, the device can be operated and configured via a web
browser service interface (CDI-RJ45) or WLAN interface. The structure of the operating
menu is the same as for the local display. In addition to the measured values, status
information on the device is displayed and can be used to monitor device health.