EasyManua.ls Logo

Epson Stylus Pro 4400 - C593_SUB-C Board; Releasing FFC; C593_SUB-C Board Connector Locations

Epson Stylus Pro 4400
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 238
4.2.4.5 C593_SUB-C Board
1. Remove "Cover, Side, Left" (p216).
2. Release the FFC from the three clamps.
3. Disconnect all connectors/harnesses on the "C593_SUB-C Board".
Note 1: Refer to Figure 4-47 for connector positions.The CN 45 is not used.
2: When connecting harnesses to the C593_SUB-C Board, connect them in the
order shown in Table 4-8.
Figure 4-46. Releasing FFC
Figure 4-47. C593_SUB-C Board Connector Locations
Table 4-8. Connectors/Harnesses Connected to C593_SUB-C Board
Connection
Order
Connector
No.
Color/
Mark
Number
of Pins
Connection Socket
1 CN38 MB 7 CSIC_L1 Board (Matte Black)
2 CN40 C 7 CSIC_L2 Board (Cyan)
3 CN41 M 7 CSIC_L3 Board (Magenta)
4 CN44 Y 7 CSIC_L4 Board (Yellow)
5 CN201 - 28 C593 MAIN Board (CN53)
6 CN200 - 15 C593 MAIN Board (CN52)
7 CN24 White 4 PF Linear Encoder Sensor
8 CN37 Black 2 I/H Lever Sensor (Left)
9 CN30 Yellow 3 ASF Phase Sensor
10 CN28 White 2 Paper Eject Phase Sensor
11 CN32 Red 3 PG Phase Sensor
Each "Harness, CSIC" (CN38, CN40, CN41, CN44) is marked
with its corresponding ink name. Refer to Table 4-8 and
connect the harnesses properly.
Ink Names
Clamps
FFC
CN45
CN24
CN37
CN28
CN200
CN201
CN30
CN44
CN41
CN40
CN38
CN32

Table of Contents