Disassembly & Assembly Disassembly Procedures 286
1. Remove "Scale, CR" (p281).
2. Move the "Carriage Unit" to match the sensor section on the rear of the
"Carridge Unit" with the cutout of the "Cover, Rear".
(Refer to Figure 4-106.)
3. Place the "CR SUS PLATE SUPPORT TOOL" on both sides of the
"Carriage Unit" as shown in Figure 4-82. (Refer to Figure 4-106.)
For the setting of the "CR SUS PLATE SUPPORT TOOL", refer to Figure
4-82 in "4.2.7.1 Carriage Unit (p266)".
4. Release the tension of the "Belt, CR" to remove the "Belt, CR" from the
pinion gear of the "Motor Assy., CR".
(Refer to "4.2.7.2 Motor Assy., CR" (p270).) (Refer to Figure 4-107.)
Figure 4-106. CR SUS PLATE SUPPORT TOOL Set Position
Figure 4-107. "Belt, CR" Removal
CR SUS PLATE SUPPORT TOOL
Belt, CR
Pinion Gear