EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 352
4.2.9.5 PE Sensor
1. Remove "Release Unit" (p343).
2. As seen from the printer rear surface, release the two left "Extension
Spring, 8.08"s from hooks on the frame. (Refer to Figure 4-213.)
3. Peel off acetate tape securing the FFC. (Refer to Figure 4-213.)
4. Remove the screw securing "Holder, Detector, PE".
(Refer to Figure 4-213.)
C.B.S. 3x6: 1 pc.
5. Slide "Holder, Detector, PE" to the rear side, release the two hooks of the
"Holder, Detector, PE" from the two frame notches and then remove
"Holder, Detector, PE" from the frame. (Refer to Figure 4-214.)
Figure 4-213. Holder, Detector, PE Removal_1
Figure 4-214. Holder, Detector, PE Removal_2
C A U T I O N
When performing the following step, be careful not to
scratch the FFC with the screwdriver.
Hooks
Extension Spring, 8.08
Extension Spring, 8.08
Acetate Tape
C.B.S. 3x6
Holder, Detector, PE