EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 305
4.2.8.5 I/H Right Unit / I/H Lever Sensor (Right)
1. Remove "Panel, Front/Panel Unit" (p219).
2. Open "Cover, I/H, Right".
3. Hold both ends of "Cover, I/H, Right" and disengage each side from the
hinge sockets. (Refer to Figure 4-136.)
4. Remove the screw securing the "I/C, Lock Lever, Knob, Right" and remove
the "I/C, Lock Lever, Knob, Right".
(Refer to Figure 4-137.)
C.B.P. 3x6: 1 pc.
Figure 4-136. Cover, I/H, Right Removal
Figure 4-137. I/C, Lock Lever, Knob, Right Removal
C A U T I O N
When performing the following work, remove ink out of the
ink path before removing the "IH Right Unit". Refer to
Chapter 5 “Adjustment” (p.366) to know how to remove ink.
C H E C K
P O I N T
The 4-color model is not equipped with this unit.
Refer to "4.2.11.2 Cover, Front, Right 4 Color (4-color Model)
(p365)" for information on how to remove the I/H Right Unit.
The "I/C, Lock Lever, Knob, Right" has upward and
downward directions. Install it in the correct direction.
Release Mark: Top
Set Mark: Bottom
Hinge Sockets
I/C, Lock Lever, Knob, Right