EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 277
4.2.7.6  Multi Sensor
1. Remove "Cover, Side, Left" (p216).
2. Move "Carriage Unit" to center of printer. 
(Refer to "4.2.4.3 C593_SUB Board" (p234).)
3. Remove the two screws securing "Multi Sensor" to the "Carriage Unit".
(Refer to Figure 4-93.)
 C.B. (P2) 3x6: 2 pcs.
4. While holding the "Multi Sensor" so as not to drop, and move the "Carriage 
Unit" to the left end of the printer keeping clear of the platen.
5. Remove the "Multi Sensor" from the "Carriage Unit" in the downward 
direction. (Refer to Figure 4-94.)
6. Disconnect the connector connected to the "Multi Sensor" and remove the 
"Multi Sensor". (Refer to Figure 4-95.)
Figure 4-93. Screws Securing Multi Sensor
Figure 4-94. Multi Sensor Removal
Figure 4-95. Connecting Status of Multi Sensor Connector
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (p.366) and 
perform specified adjustments after replacing or installing a 
"Multi Sensor".
C.B. (P2) 3x6
Connector