Disassembly & Assembly Disassembly Procedures 355
6. Release the two tabs securing "Rear Manual Insertion Sensor" and remove 
"Rear Manual Insertion Sensor" from "Installation Plate, Detector, Rear". 
(Refer to Figure 4-218.)
7. Disconnect the connector from "Rear Manual Insertion Sensor". 
(Refer to Figure 4-219.)
Figure 4-218. Installation Plate, Detector, Rear Removal
Figure 4-219. Rear Manual Insertion Sensor Removal
 Route "Rear Manual Insertion Sensor" harness as shown 
in Figure 4-219.
 Release the harness tube from the "Installation Plate, 
Detector, Rear".
Tabs
Rear Manual 
Insertion Sensor
Tube