EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 274
4.2.7.4 Motor Assy., PG
1. Remove "Cover, Side, Right" (p217).
2. Peel off the acetate tape and release the tab at the lower part of the
"Sheet, Ink, Stopper, C" from the U-shaped cutout of the "Frame, Base,
Side, Right". (Refer to Figure 4-89.)
3. Disconnect relay connector. (Refer to Figure 4-90.)
4. Remove the acetate tape securing the harness, and release "Harness,
CSIC" and "Motor Assy., PG" harness from "Duct, Air, C" hook.
(Refer to Figure 4-90.)
5. Release "Motor Assy., PG" harness and "Mount Assy., Plate, Motor, ASF,
SP" harness from the U-shaped cutout of the "Frame, Base, Side, Right".
(Refer to Figure 4-90.)
6. Peel acetate tape and release "PG Motor" harness. (Refer to Figure 4-90.)
Figure 4-89. Sheet, Ink, Stopper, C Release
Figure 4-90. Releasing the Harness
Frame, Base, Side, Right
Sheet, Ink, Stopper, C
Duct, Air, C
Harness, CSIC
Motor Assy., PG Harness
Step 3
Step 4

Table of Contents