14. Disconnect "Harness, CSIC"s (4 connectors: CN38, CN40, CN41, CN44)
and "I/H Lever Sensor (Left)"s harness (CN37: black, 2 pin) from
"C593_SUB-C Board".
(Refer to "4.2.4.5 C593_SUB-C Board" (p238).)
15. Peel two pieces of acetate tape and release the four "Harness, CSIC"s and
"I/H Lever Sensor (Left)"s harness. (Refer to Figure 4-131.)
16. Pull the "I/H Left Unit" forward from the printer while pulling the four
"Harness, CSIC" and "I/H Lever Sensor (Left)" harness from the hole of the
frame.
Figure 4-131. Releasing the Harnesses
Figure 4-132. I/H Left Unit Removal
Acetate Tapes
Harness, CSIC
I/H Lever Sensor (Left) Harness
Pull harness through this hole