ES910.3-A - User’s Guide 80
ETAS Technical Data
7.6.3 Compatibility between Rapid Prototyping Models and ES910.3-A Firmware
Rapid prototyping models that were generated with INTECRIO V3.2.0 / ASCET-
RP V6.1.2 or with earlier versions, cannot be executed on ES910.3-A systems
containing the firmware from HSP V9.4.0 or from newer HSP versions.
If you want to use the aforementioned Rapid Prototyping models and INCA_EIP
databases containing such models, they have to be generated again with INTE-
CRIO V4.0.0 / ASCET-RP V6.1.3 or with newer versions so that the models can
be executed on ES910.3-A systems containing the firmware from HSP V9.4.0 or
newer HSP versions.
In the reverse case, Rapid Prototyping models generated with INTECRIO V4.0 /
ASCET-RP V6.1.3 or with newer versions do not run ES910.3-A systems contain-
ing firmware from HSP versions earlier than HSP V9.4.0.
7.6.4 Information about the Combination ES910.3-A with ES715 Drive Recorder
Modules with Firmware of Version HSP V8.0.x or older
The combination of the modules ES910.3-A and ES715 Drive Recorder works
together if the modules contain firmware of version HSP V8.0.x or older.
Modules with Firmware of Version HSP V8.1.x or newer
The combination of the modules ES910.3-A and ES715 Drive Recorder does no
longer work together starting with HSP V8.1.x or newer since the working mem-
ory of the ES715 Drive Recorders is too small.
Please note that the described joint operation of both modules is neither
released nor supported by the Technical Support.