Multimeter Tests
138 MAX-635G
Isolation
User Defined Voltage (T-R, T-G, R-G/A-B, A-E, B-E) allows you to
enter a voltage value between 50 and 125 V (50 and 500 V if HIVOLT)
for Tip to Ring wire Pair.
Minimal Soak Time sets a soak period of time from 1 to 60 seconds.
When the test duration reaches the Minimal Soak Time, the pass/fail
status is displayed and then periodically refreshed, until you stop the
test.
Threshold Settings button opens a new page that allows you to set
isolation thresholds for each pair.
Result displays a snapshot of the pass/fail status, Resistance and a
Soak Counter for each selected wire pair. While running the test, the
counter displays the soak period by the second, for the wire pair(s)
under test.
Test Status displays the current state of measurement or an error
message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press the left/right arrow keys to view and select the options.
OR
3. Press on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4. Press to confirm the value.