Noise Tests
192 MAX-635G
WB Impulse Noise
WB Impulse Noise
The wideband impulse noise test allows you to measure impulse noise on
the circuit under test.
Count
The Count function displays and updates results in
real time, for the length of time set in Test Duration or
less if you stop the test. The last valid results then
remain displayed.
Current Group is the current test group name, for
example Noise Tests.
Current Test displays the test being measured.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.
WB Noise Filter displays the filter currently
enabled. Options are: None, ISDN-E, HDSL-F, ADSL-G, ADSL, ADSL2+,
VDSL, VDSL2-8, VDSL2-12, VDSL2-17, VDSL2-30.
Termination is either Ter minated, if the termination resistance is
internal to the unit, or Bridging if additional termination resistance is
used to bridge onto live circuits with minimal interruption.
Termination Resistance lists the resistance of the dummy load
connected to the line.
Test Duration allows you to set the length of time to run the test from a
list of values. If UFED Control option is enabled, the maximum value is
limited to15 min.

Table of Contents