SmartR™ Features
154 MAX-635G
Pair Detective
Summary
The Summary page displays a summary of the pass/fail status,
DC-Voltage/Current and Isolation for each selected inactive wire pair, as
well as other detailed results of the Pair Detective test. Plain language
results are displayed as the test progresses, with color coding to draw
attention to faults. You may view raw results by selecting the Multimeter
tab at the bottom of the screen.
TDR is also automatically started in auto-mode, to locate the nearest
significant event/reflection; it remains on and ready for your usage upon
test completion (select the TDR tab to use).
Pair Detective runs two unique tests found nowhere else in the MaxTester:
Corrosion and Wet detect. Corrosion detect identifies the presence of
one-sided corrosion or series resistance (such as a high resistive or partial,
dirty open), while Wet detect tells you if a fault (faulted splice joint or
module, for example) is damp. (Pair Detective cannot identify flooded
cable sections; use TDR for this problem.)
Pair Detective can find or indicate the following faults/conditions:
Device Detection results for the following providers, set up in the
Application Settings\Standard\NTD Provider. Possible results include
No Device Detected, Short, Disabled, and Unknown Device. Results
specific to each parameter include:
None
Phone On/Off Hook
France
FT ITD
FT ITD and Phone On/Off Hook
Phone On/Off Hook