Programmer’s Guide, cont’d
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
4-8
Command/Response Table for SIS Commands
Symbol definitions
Symbolsareusedthroughoutthetabletorepresentvariablesinthecommand/
response fields. Command and response examples are shown throughout the table.
N
Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are
reported as 2-digit numbers in the response.
]
= CR/LF(carriagereturn/linefeed)(hex0D0A)
}
= Carriagereturn(nolinefeed,hex0D))
= Spacecharacter
E
= Escapekey(hex1B)
X!
= Inputnumber 01–(maximumnumberofinputsforyourmodel)
X@
= Inputnumber(fortie)
00–(maximumnumberofinputsforyourmodel)(00=untied)
X#
= Outputnumber 01–(maximumnumberofoutputsforyourmodel)
X$
= Mute,Lockmode,powersupply 0=off/mode0/notOK
1=on/mode1/OK
2=mode2
X%
= Audiogain 0–24(1dB/step)
X^
= NumericdBvalue –18to+24(45stepsofgainorattenuation)(default=0dB)
X&
= Audioattenuation 1–18(1dB/step)
X*
= Volumeadjustmentrange 0–64(1dB/stepexceptfor0-to-1,whichis22dB)
(default=64[0dB])
(Seethetableonpage4-11.)
X(
= Globalorroompreset# 00-32,10maximumforaroompreset(00=currentconguration)
N
A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from
memory, it becomes the current configuration.
X1)
= Room#(forroompresets) 10max.(Eachcanhaveupto10presets(
X(
s) assigned.)
N
A Room is a subset of operator-selected outputs that relate to each other. The CrossPoint or MAV Plus switchers support up to 10
rooms, each of which can consist of from 1 to 16 outputs.
X1!
= Name 12charactersmaximumforinput,output,andglobalpresetnames
11 characters maximum for room names
Upper-andlower-casealphanumericcharactersand
_/andspacesarevalid.
N
The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X1@
= Video/audiomute: 0=nomutes
1=videomute
2=audiomute
3=videoandaudiomute
X1#
= Syncfrequency xxx.xx(frequencyinhZ[V]orkHz[H])
X1$
= Connectionstatus 0=noinputconnected
1=inputconnected
X1%
= RGBdelayinterval Delayin1/2secondincrements(10maximum)
X1^
= Group#(forI/Ogrouping) 1through4groups(0=nogroup)
X1&
= Inputs Totalnumberofinputsforthisswitcher
X1*
= Outputs Totalnumberofoutputsforthisswitcher
X1(
= Partnumber 60-nnn-nn(SeeappendixB,“ReferenceInformation”.)
X2)
= Firmwareversionnumbertoseconddecimalplace(x.xx)
X2!
= Verbosermwareversion-description-uploaddate/time.
SeetheQuery controller firmware version (verbose)commandonpage4-19.
X2@
= Voltage Positiveornegativevoltageandmagnitude
X2#
= Temperature DegreesFahrenheit
X2$
= Fanspeed RPM