Programmer’s Guide, cont’d
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
4-8
Command/Response Table for SIS Commands
Symbol definitions
Symbolsareusedthroughoutthetabletorepresentvariablesinthecommand/
response fields. Command and response examples are shown throughout the table.
N
Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are
reported as 2-digit numbers in the response.
]
= CR/LF(carriagereturn/linefeed)(hex0D0A)
}
= Carriagereturn(nolinefeed,hex0D))
= Spacecharacter
E
= Escapekey(hex1B)
X!
= Inputnumber 01–(maximumnumberofinputsforyourmodel)
X@
= Inputnumber(fortie)
00–(maximumnumberofinputsforyourmodel)(00=untied)
X#
= Outputnumber 01–(maximumnumberofoutputsforyourmodel)
X$
= Mute,Lockmode,powersupply 0=off/mode0/notOK
1=on/mode1/OK
2=mode2
X%
= Audiogain 0–24(1dB/step)
X^
= NumericdBvalue –18to+24(45stepsofgainorattenuation)(default=0dB)
X&
= Audioattenuation 1–18(1dB/step)
X*
= Volumeadjustmentrange 0–64(1dB/stepexceptfor0-to-1,whichis22dB)
(default=64[0dB])
(Seethetableonpage4-11.)
X(
= Globalorroompreset# 00-32,10maximumforaroompreset(00=currentconguration)
N
A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from
memory, it becomes the current configuration.
X1)
= Room#(forroompresets) 10max.(Eachcanhaveupto10presets(
X(
s) assigned.)
N
A Room is a subset of operator-selected outputs that relate to each other. The CrossPoint or MAV Plus switchers support up to 10
rooms, each of which can consist of from 1 to 16 outputs.
X1!
= Name 12charactersmaximumforinput,output,andglobalpresetnames
11 characters maximum for room names
Upper-andlower-casealphanumericcharactersand
_/andspacesarevalid.
N
The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X1@
= Video/audiomute: 0=nomutes
1=videomute
2=audiomute
3=videoandaudiomute
X1#
= Syncfrequency xxx.xx(frequencyinhZ[V]orkHz[H])
X1$
= Connectionstatus 0=noinputconnected
1=inputconnected
X1%
= RGBdelayinterval Delayin1/2secondincrements(10maximum)
X1^
= Group#(forI/Ogrouping) 1through4groups(0=nogroup)
X1&
= Inputs Totalnumberofinputsforthisswitcher
X1*
= Outputs Totalnumberofoutputsforthisswitcher
X1(
= Partnumber 60-nnn-nn(SeeappendixB,“ReferenceInformation”.)
X2)
= Firmwareversionnumbertoseconddecimalplace(x.xx)
X2!
= Verbosermwareversion-description-uploaddate/time.
SeetheQuery controller firmware version (verbose)commandonpage4-19.
X2@
= Voltage Positiveornegativevoltageandmagnitude
X2#
= Temperature DegreesFahrenheit
X2$
= Fanspeed RPM

Table of Contents

Other manuals for Extron electronics CrossPoint 450 Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics CrossPoint 450 Plus Series and is the answer not in the manual?

Extron electronics CrossPoint 450 Plus Series Specifications

General IconGeneral
BrandExtron electronics
ModelCrossPoint 450 Plus Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals