Command/response table for IP-specific SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
IP setup commands (continued)
Sete-maileventsfor
recipient
EX4!
,
X4#
,
X4$
,
X4$
,...,
X4$
EM
}
Ipe
X4%]
You must first have set
an e-mail recipient for the
e-mail account number
(
X4!
), using the separate
Sete-mailrecipient(CR)
command.
Example:
CrossPoint 450 Plus 3232
E
72,3,1,2,8,32,98,99,EM
}
E-mailaccount#72,JSmith,
willreceivefail/missingand
xed/restoredmessagesfor
inputsignals1,2,8,and32;
fans; and power supplies.
Ipe•Jsmith@folklore.net
]
Read e-mail events for
recipients
EX4!
EM
} X4$
,
X4$
,
X4$
, ... ,
X4$]
Response description:
Notify-what?inputs1-32(inputsabovethematrixsizearealwayszero)fansPS
]
Example:
CrossPoint 450 Plus 3232
E7@
EM
}
Seebelow
Response:
Notify failed and fixed
3, 11000001000000000000000
01Input: 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Fans
Power Supplies
E-mail input 8 status E-mail power supply and fan statusIgnore input 16
00000000111
Example:
MAV Plus 1616
E7@
EM
}
Seebelow
Response:
Notify failed and fixed
3, 11000001000000001
01Input: 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
Power Supply
E-mail input 8 status Ignore input 16
SetDHCPonoroff
EX4^
DH
}
Idh
X4^]
ReadDHCPon/offstatus
E
DH
} X4^]
Setserialportparameters
EX4&
*
X4*
,
X4(
,
X5)
,
X5!
CP
}
Cpn
X4&
•Ccp
X4*
,
X4(
,
X5)
,
X5!]
Read serial port parameters
EX4&
CP
}
X4*
,
X4(
,
X5)
,
X5!]
Congureowcontrol
EX4&
*
X5$
,
X5%
CF
]
Cpn
X4&
•C
X5$
,
X5%]
Readowcontrol
E
CF
X5$
,
X5%]
Configure receive timeout
EX4&
*
X5^
,
X5&
CE
]
Cpn
X4&
•Cce
X5^
,
X5&]
Read receive timeout
E
CE
X5^
,
X5&]
Setmode
EX4&
*
X5@
CY
}
Cpn
X4&
•Cty
X5@]
Read mode
EX4&
CY
} X5@]
Setverbosemode
EX5#
CV
}
Vrb
X5#]
Read verbose mode
E
CV
} X5#]
Configure current port
timeout
E
0*
X5*
TC
}
Pti0*
X5*]
Read current port timeout
E
0TC
} X5*]
CongureglobalIPport
timeout
E
1*
X5*
TC
}
Pti1*
X5*]
ReadglobalIPporttimeout
E
1TC
} X5*]

Table of Contents

Other manuals for Extron electronics CrossPoint 450 Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics CrossPoint 450 Plus Series and is the answer not in the manual?

Extron electronics CrossPoint 450 Plus Series Specifications

General IconGeneral
BrandExtron electronics
ModelCrossPoint 450 Plus Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals