EasyManua.ls Logo

Festo SPC200 - Page 156

Festo SPC200
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Commissioning positioning systems
4−42
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
Loading the axis parameters into the SPC200
If the hardware configuration of the SPC200 corresponds to
the project, you can load individual data into the SPC200 in
active Online mode.
You can load individual data into the SPC200 as follows:
1. Activate the Online mode (command [Online] [Online
mode] or click the button Online mode"
in the toolbar.
2. Select the command [Axis parameters] in the menu
[Online] from the overlapping menu [Download], in order
to load all the configured data for all the axes in the
dialogue window Parameter set for the .. −axis" into the
SPC200.
3. Read the warning displayed. You can load the selected
data into the
SPC200 with Continue"; you can terminate
the transmission with Cancel".
While the data are being loaded into the SPC200, the
progress of the data transmission is shown in a window.
If an error occurs during transmission, acknowledge the
message and repeat the process.

Table of Contents