Contents and general instructions
XXXI
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
Step 3
Check the tubing (optional)
(see also section 4.4)
To do this carry out the movement test (the following descrip
tion is valid for operating system V4.6).
1. Apply a 0−signal at the input ENABLE.
2. If necessary, activate the online mode (Command [Online]
[Online mode]).
3. Select the command [Online] [Diagnosis] [Movement test
..−axis] for the desired axis.
4. Select the desired axis in the dialogue window
Movement test".
5. Apply a 1−signal at the input ENABLE.
6. Carry out the movement test: Modify the valve voltage
and check the direction of movement.
A 0−signal at ENABLE will set the valve voltage to 5 V and
interrupt the movement test (with fault message).
7. Conclude the
movement test for the selected axis with
Exit".
8. Apply a 0−signal at the input ENABLE.
Step 4
Only with pneumatic drives with incremental measuring
system (e.g. type DNCI−...): Carry out reference travel
(see also section 4.5)
Reference travel must be carried out for commissioning
(Menu [Online] [Commissioning] [Reference travel]).