web-based configuration utility as well as capture and transmit a period of raw video during validation
to assess system accuracy.
Ongoing Bandwidth Requirements
To minimize bandwidth requirements on an on-going basis, 3D Gen 2 is capable of transmitting metric
data in configurable increments. Independently- configurable data capture and data transmission
frequencies reduce network overhead, and semi-random distribution of data packets decreases peaks in
network demand. On an on-going basis, each sensor only requires about 0.05kbps of bandwidth for
analytics.
Logical Port Specifications
The following logical ports are the default configuration for the 3D Gen 2 sensor.
Data Description
a
Default Port Protocol Direction
XML data, time synchronization, diagnostics/logging TCP 2010
b
HTTP Outbound
Validation video
TCP 21 FTP
Outbound
TCP 990 FTPS
Software upgrade UDP 69 TFTP Outbound & inbound
Software upgrade, web-based configuration utility
TCP 80 HTTP Inbound
TCP 443 HTTPS
c
Inbound
Ping ICMP Inbound
Device Manager (optional) TCP 2375 HTTP Outbound
a
All listed port numbers are configurable.
b
Used by Device Adapter, but can be sent over another port as desired.
c
We recommend using HTTPS for all data traffic to provide optimal security of your data.