Brickstream® 3D Gen 2 Installation Guide
June 2021
98
Note: An acceptable 3D Gen 2 installation must also meet all
criteria listed in the requirements section of this document.
Requirements
To ensure successful installation, the following requirements must be met:
n Unless mentioned differently on the design, 3D Gen 2 needs to be installed at 4.2m (13ft 9in.)
AFF to the bottom of the 3D Gen 2.
n The RAM mount used to attach the 3D Gen 2 to the pole allows for additional drop.
n Final height to the bottom of the pole AFF should be within 7.6cm to 15.2cm (3 to 6in.)
above the 3D Gen 2 install height.
n Poles/sensors must be positioned as per design to capture the precise areas of interest.
n Mounting hardware must be able to accommodate the RJ-45 connector on the patch cables.
n Pole diameter must be no less than 1.9cm ”) and no greater than 3.8cm (1 ½”).
n Installed 3D Gen 2 must not have any movement or swaying from normally occurring conditions
including nearby fan operation and air circulation.
Warning! It is very important that poles are secured in
place to ensure accurate performance of the 3D Gen 2. Any
movement of the 3D Gen 2 affects its coverage of the areas
of interest, and the precision of the analytics may be
dramatically decreased.
n Installations must be uniform throughout (i.e. poles hanging same length, mounts set on same
sides, cables looped similarly etc.) and neatly assembled.
n Installation methods must comply with current national and site regulations and shall be carried
out by technicians who are appropriately qualified.
n Safety cables and other preventive measures should be used at the discretion of the end client
and their chosen installation partner.
Installation Instructions
1. Terminate the CAT5e from the home run (network closet) into a CAT5e Surface Mount Jack
(Biscuit Jack) above each sensor's location.
2. Run a patch cable through the EMT down to the 3D Gen 2 as shown in the following image.