Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
50
Step 8 of 10—Calibration (Part 2)
1. In the video pane, position the green box following these guidelines:
a. Ensure that area within the box is as large as possible while only containing the floor, no
walls or other objects, and minimal or no pink shaded (undefined) areas.
b. If the box includes displays, walls, other objects, or pink shaded areas, click it and drag to
a different section of the image. If needed, you can click on the corners of the calibration
box and resize it, or click in the middle of the box and move the entire box so that it only
covers the floor.
2. Click Auto-Calibrate. After several seconds, the sensor automatically calculates the height (cm),
and X and Y rotation.
3. Look at the height and rotation numbers to ensure that they are reasonable using the following
guidelines:
n Calculated height should be within 20% of visual height estimate.
n X and Y rotation should be within 10 degrees of visual angle estimate.
4. Click Save &Next.
Note: This information is also on the Calibration page.