Brickstream® 3D Gen 2 Installation Guide
June 2021
47
Step 5 of 10—Device Manager
If using the FLIRDevice Manager, enter the following information to point the sensor to the Device
Manager Server.
1. Click the Enabled switch to ON. The fields become active.
2. In the IP or Host Name field, enter the IP address or name of the host where the Device Manager
Server is running.
3. In the Port Number field, enter the port number that you used when you started the Device
Manager Server or use the port number provided to you by your Network Administrator. The
default value is 2375.
4. In the APIToken field, enter the token. An API token is a cryptic string of up to 255 characters,
used to authenticate access to the HTTPS server.
5. To enable encryption, click the Encryption switch to ON and enter the SNIHost Name. An
encrypted connection to the Device Manager is supported on Device Manager version 5.0 or later.
6. In the Connect Frequency field, enter the frequency (in milliseconds) that the sensor checks the
Device Manager Server for connection requests. The default value is 10000.
7. The default setting for Timeout is 60 seconds. If your network is slower, increase this value to
prevent the sensor from timing out before connecting to the Device Manager server.
8. Click Test Settings to test the connection of the Device Manager server. A Device Manager server
request is immediately sent. A success or failure message is displayed at the top of the page
depending on the outcome.
9. Click Save &Next.
Note: This information is also on the Settings->Basic Settings
page, Device Manager tab.