Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
80
5. If the sensor needs to send data feeds to a specific URL address in the HTTP POST, in the
Destination URL/directory field enter the URL address.
Note: Use ‘/’ if you have not been directed to change this
field. This allows your IT department to use the same port
for multiple sensors and filter the traffic by the URL in the
HTTP POST.
6. Click the Delivery Enabled switch to ON to have the data delivered.
7. Click the Use Wi-Fi MACAddress switch to ON if using the Wi-Fi MACAddress. If OFF, the
sensor's MACAddress is used. Both MAC addresses are visible on the sensor's home page.
8. Leave the Data Packets Only switch at ON(default) to post packets to the server only when data
has been captured. Switch to OFF if you want posts made to the server even if the data payload is
empty.
9. If you want the MAC address to be encrypted, from the Encryption Type drop-down select an
encryption algorithm.
10. Click the Data Encryption switch to ON to have the data delivered over an SSL connection. Enter
the SNI Host Name.
11. Click Test Settings to confirm entries.
12. Click Save.
Setting Traffic Map Delivery
The sensor sends XML data packets containing traffic and dwell map metric data to a configured
delivery address and port number at a configurable time interval. Use the Traffic Maps Settings page to
set and edit this information.
1. Open the web interface to the Data Delivery > Traffic Maps Settings page.
2. Click the Traffic Maps switch to ON.
The fields become active.