EasyManua.ls Logo

FLIR BRICKSTREAM 3D Gen 2 - Setting Alert Delivery Options

FLIR BRICKSTREAM 3D Gen 2
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
71
The default value is 1,000 ms (1 second).
8. To only send updates if the count changes in any zone, click the Skip Inactivity switch to ON.
9. If you want the data stream to be encrypted:
a. Click the Encryption switch to ON.
b. In the SNI Host Name field, enter the Server Name Indication (SNI) hostname or IP address
for the host.
10. In the APIToken field, enter the token. The Delivery Protocol must be set to HTTP for this field to
be active. An API token is a cryptic string of up to 255 characters, used to authenticate access to
the HTTPS server.
11. Click Test Settings to confirm entries.
12. If required, repeat steps 2 to 11 to enter information for a second Real Time Delivery.
13. Click Save.
Setting Alert Delivery Options
The sensor can deliver individual alert messages each time a count line is crossed. This alerting system
is typically used to allow integrators to set up tripwire logic in which the sensor sends an alert when the
count lines are crossed to indicate intrusions or behavioral alerts.
1. Open the web interface to the Data Delivery> Alerts page.
2. Click the Alert Delivery switch to ON.
The fields become active.
3. In the IP or Host Name field, enter the IP address of the server to receive alerts from the sensor.
4. In the Port number field, enter the port number to which the sensor should attempt to deliver
alerts.
5. If the sensor needs to send alerts to a specific URL address in the HTTP POST, in the Destination
field, enter the URL address.
Note: Use / if you have not been directed to change this