Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
70
1. Open the web interface to the Data Delivery> Real Time page.
2. Click the Real Time Delivery 1 switch to ON.
The fields become active.
3. In the IPor Host Name field, enter the IP address of the server to receive data feeds from the
sensor.
4. In the Port number field, enter the port number to which the sensor should attempt to deliver data
feeds.
5. If the sensor needs to send data feeds to a specific URL address in the HTTP POST, in the
Destination URL/directory field enter the URL address.
Note: Use / if you have not been directed to change this
field. This allows your IT department to use the same port
for multiple sensors and filter the traffic by the URL in the
HTTP POST.
6. From the Delivery Protocol drop-down select the desired delivery protocol.
Option Description
VLI
The XML data is sent as a raw TCP/IP data packet. The XML data is prepared with a 4
byte VLI which contains the length of the XML file to follow. The VLI interface does not
require an acknowledgment.
HTTP
The XML data is contained within an HTTP POST the same HTTP structure as a
standard post to the server. The application must return an HTTP acknowledgment.
7. In the Delivery Frequency field, enter the number of milliseconds between connection attempts
from the sensor to the Device Manager Server.