EasyManua.ls Logo

FLIR BRICKSTREAM 3D Gen 2 - Setting Email Delivery Options

FLIR BRICKSTREAM 3D Gen 2
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
72
field. This allows your IT department to use the same port
for multiple sensors and filter the traffic by the URL in the
HTTP POST.
6. From the Delivery Protocol drop-down, select the desired alert protocol.
Option
Description
VLI
Sends alert as plain text with a variable length indicator (VLI) at the beginning of the
message.
HTTP
POST
Sends an HTTP POST to the URL address specified in the Destination field.
TCP
Sends alerts via TCP data delivery method, which is compatible with the AXIS camera
alert delivery message format. See the Programmer’s Guide for more details.
HTTP
Sends an HTTP GET to the URL address specified in the Destination field. The specific
page request is defined on the Counting page.
7. In the Inter Alert Delay Time field, enter the number of milliseconds the alert system delays
between sending consecutive alerts. This threshold is used when multiple people cross the count
lines at the same time or close together. The sensor buffers and sends each alert when the delay
time expires. Accepted values are from 0 to 30,000 milliseconds.
8. From the Count Delivery drop-down, select None, Counts, or Counts with MAC to set whether the
alert message should contain the total count values for the count lines and if this should include
the MACaddress.
Note: If enabled, the alert message contains the total enter
and/or exit counts since the last reboot. The number is not
the daily count total.
9. In the APIToken field, enter the token. The Delivery Protocol must be set to HTTP or HTTPPost
for this field to be active. An API token is a cryptic string of up to 255 characters, used to
authenticate access to the HTTPS server.
10. Click Test Settings to confirm entries.
11. Click Save.
Setting Email Delivery Options
The sensor can automatically send aggregated daily metric data to an email account.
1. Open the web interface to the Data Delivery> Email page.
2. Click the Email Delivery switch to ON.
The fields become active.

Table of Contents

Related product manuals