Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
16
The following figures show the sensor location and coverage areas for sensors with and without tilt.
Sensors without tilt have a rectangular coverage area with a 4:3 aspect ratio.
Without Tilt
Without Tilt
With X Tilt
With Y Tilt
Tilting a sensor can increase coverage substantially, within limitations:
n Generally a tilt of 5° to 10° does not impact accuracy
n Tilt greater than 10° requires advanced licensing and impacts accuracy, especially in high-volume
environments where occlusion is constantly present
Additional tools available from your Brickstream Representative to assist you in determining coverage
area include:
n Coverage Calculator for the sensor (shown below)
n Simple Installation Calculator (shown in Performing a Site Survey )
n Minimum Distance Calculator for sensor with tilt
Coverage Calculator
For exact coverage calculations, use the Coverage Calculator as follows:
1. Identify the dimensions of the desired coverage area.
2. Click the desired Coverage Tables tab to determine the correct lens type for the desired
installation height.
3. Click the Coverage tab.